View Enquiry: BE 2022-3009-035


Contract Details
Contract Number
2022-3009
Region
West
Tender Owner
MTO Capital
Location
N\A
Highway
401
Length
0
QMS Declaration
Yes
Option A or B bidding
No
Contract Description
DESIGN BUILD MINOR - Grading, Drainage, Hot Mix Paving, Structure and Electrical.
Tender Instructions
EXPRESSION OF INTEREST Must be received electronically as prescribed in the Expression of Interest document by 3:00:00 P.M. local time on; March 30, 2022
Contract Dates
Tender Advertise
23-Feb-2022
Tender Opening
03-Aug-2022 at 01:30:00 PM
TRF Submission Opening
06-Jul-2022
TRF Submission Closing
29-Jul-2022 at 12:00:00 PM

Enquiry Details
Enquiry Date
03-Jun-2022 at 02:13:43 PM
Type
Other
Subject
Bridge Deck Thickness
Enquiry
Item K of Section 2.4.8.1 (Bridge Design and Construction) notes that the bridge deck thickness shall be a minimum of 235 mm; however, the use of a conventional cast-in-in place concrete deck is permitted in this same item. Please confirm that the 235 mm minimum thickness only applies to the option with cast-in-place deck panels and that a 225 mm minimum thickness applies to conventional cast-in-place concrete deck.

Response Details
Response Status
Completed
Response Date
08-Jun-2022 at 03:07:11 PM
Response
Full depth cast-in-place concrete deck requires a minimum thickness of 225mm. Partial depth precast deck panels placed over box girder voids with conventional cast-in-place concrete placed on panels, and full depth cast-in-place deck placed between boxes and overhangs shall have a minimum thickness of 235mm.