View Enquiry: BE 2022-5008-012


Contract Details
Contract Number
2022-5008
Region
Northeastern
Tender Owner
MTO Capital
Location
From Trout Lake Road Northerly to Estaire Road Interchange
Highway
7279
Length
17.69
QMS Declaration
Yes
Option A or B bidding
No
Contract Description
Grading, Drainage, Electrical
Tender Instructions
Contract Dates
Tender Advertise
27-Apr-2022
Tender Opening
07-Jul-2022 at 03:00:00 PM
TRF Submission Opening
09-Jun-2022
TRF Submission Closing
01-Jul-2022 at 12:00:00 PM

Enquiry Details
Enquiry Date
30-May-2022 at 10:40:21 AM
Type
Contract Drawing
Subject
Drawing Sheet 97
Enquiry
Drawing Sheet 97 shows that 12 Culverts need the granular B Type II and Granular A for Road subbase and roadbase required. However only CV29 & 30 require Granular A Roadbase and Granular B Type II subbase has been included in Q sheet in Item 14 & 15. Please quantify the Granular A Roadbase and Granular B Type II subbase required for other Culvert 4, 5, 6, 7, 8, 28, 32, 33, 38.

Response Details
Response Status
Completed
Response Date
22-Jun-2022 at 11:39:09 AM
Response
Excavation and backfill are included in the rate of the pipe culverts. Since culvert 29 is at high fill, Granular A and Granular B are quantified up to a depth of 2m from the bottom of the culvert (Q-sheet 5 and 23). Since culvert 30 is a concrete box culvert, excavation and backfilling quantity are quantified under the Q-sheet 6 and 23.