Please wait...
An error occurred while executing an action
(Check error messages on the page)

View Enquiry: BE 2021-6003-010


Contract Details
Contract Number
2021-6003
Region
Northwestern
Tender Owner
MTO Capital
Location
Windy Point Bridge (Site No. 45X-0077/B0) - Hwy 11, 10.5km west of Hwy 502
Highway
11
Length
0
QMS Declaration
Yes
Option A or B bidding
No
Contract Description
Grading, Granular Base, Hot Mix Paving, Structure Rehabilitation
Tender Instructions
Contract Dates
Tender Advertise
24-Feb-2021
Tender Opening
01-Apr-2021 at 01:30:00 PM
TRF Submission Opening
04-Mar-2021
TRF Submission Closing
26-Mar-2021 at 12:00:00 PM

Enquiry Details
Enquiry Date
25-Mar-2021 at 03:22:11 PM
Type
Other
Subject
Clarification
Enquiry
As described in the drawings, the sequence, you have to pour the UHPC after placing 6 panels and then wait until it reaches 80MPa. It makes it impossible to finish the works before the completion date. Would the Ministry consider letting us pour the UHPC after we finished placing the concrete panels on stage A and then stage B and so on.

Response Details
Response Status
Completed
Response Date
29-Mar-2021 at 09:20:17 AM
Response
The sequence shall be as indicated on the Contract Drawings. Requests for minor sequencing revisions may be assessed during construction. As noted in Construction Sequence Note 8, an alternative deck panel installation and pouring sequence is permitted to allow the Contractor additional flexibility as well as an opportunity to expedite the works.