View Enquiry: BE 2019-6004-004


Contract Details
Contract Number
2019-6004
Region
Northwestern
Tender Owner
MTO Regional
Location
Beaver Creek Bridge (Site No. 41S-0055/B0), Griffiths Road, 1.2 km north of Hwy 594; McLeod Creek Bridge (Site No. 41S-0112/B0), Wabigoon Lake Road, 1.4 km east of Hwy 502.
Highway
N/A
Length
0
QMS Declaration
Yes
Option A or B bidding
No
Contract Description
Grading, Structural Replacement
Tender Instructions
Contract Dates
Tender Advertise
26-Jul-2019
Tender Opening
26-Aug-2019 at 11:30:00 AM
TRF Submission Opening
26-Jul-2019
TRF Submission Closing
23-Aug-2019 at 12:00:00 PM

Enquiry Details
Enquiry Date
19-Aug-2019 at 08:31:06 AM
Type
Contract Drawing
Subject
New Panel Bridge Spec
Enquiry
Drawing Sheet 11 indicates 3366mm length thrie beam which is custom lengths. This is a change from what is typically provided where standard lengths of 3.81m (12ft-6in.) are provided and drilled to suit on site. Is the new customized lengths required or can the standard lengths drilled to suit on site be provided as per previous tenders? What is the thickness required for the back up plate shown on sheet 11? Is the plate required to be galvanized?

Response Details
Response Status
Completed
Response Date
19-Aug-2019 at 04:13:55 PM
Response
The 3366mm length of thrie beam is as specified on past sites. The length is intended to suit the truss panel spacing of the modular bridge. The lengths shown on the Contract Drawings have successfully been supplied by modular bridge manufacturers in the past. The back-up plate is a section of thrie beam rail (which is galvanized) installed as reinforcing at intermediate posts where there is no splice. This applies only at the approach ramps.